Muestra métricas de impacto externas asociadas a la publicación. Para mayor detalle:
| Indexado |
|
||||
| DOI | 10.1093/RPD/NCS139 | ||||
| Año | 2013 | ||||
| Tipo | artículo de investigación |
Citas Totales
Autores Afiliación Chile
Instituciones Chile
% Participación
Internacional
Autores
Afiliación Extranjera
Instituciones
Extranjeras
The bottleneck in data acquisition during biological dosimetry based on a dicentric assay is the need to score dicentrics in a large number of lymphocytes. One way to increase the capacity of a given laboratory is to use the ability of skilled operators from other laboratories. This can be done using image analysis systems and distributing images all around the world. Two exercises were conducted to test the efficiency of such an approach involving 10 laboratories. During the first exercise (E1), the participant laboratories analysed the same images derived from cells exposed to 0.5 and 3 Gy; 100 images were sent to all participants for both doses. Whatever the dose, only about half of the cells were complete with well-spread metaphases suitable for analysis. A coefficient of variation (CV) on the standard deviation of 15 was obtained for both doses. The trueness was better for 3 Gy (0.6 ) than for 0.5 Gy (37.8 ). The number of estimated doses classified as satisfactory according to the z-score was 3 at 0.5 Gy and 8 at 3 Gy for 10 dose estimations. In the second exercise, an emergency situation was tested, each laboratory was required to score a different set of 50 images in 2 d extracted from 500 downloaded images derived from cells exposed to 0.5 Gy. Then the remaining 450 images had to be scored within a week. Using 50 different images, the CV on the estimated doses (79.2 ) was not as good as in E1, probably associated to a lower number of cells analysed (50 vs. 100) or from the fact that laboratories analysed a different set of images. The trueness for the dose was better after scoring 500 cells (22.5 ) than after 50 cells (26.8 ). For the 10 dose estimations, the number of doses classified as satisfactory according to the z-score was 9, for both 50 and 500 cells. Overall, the results obtained support the feasibility of networking using electronically transmitted images. However, before its implementation some issues should be elucidated, such as the number and resolution of the images to be sent, and the harmonisation of the scoring criteria. Additionally, a global website able to be used for the different regional networks, like Share Points, will be desirable to facilitate worldwide communication.
| WOS |
|---|
| Public, Environmental & Occupational Health |
| Radiology, Nuclear Medicine & Medical Imaging |
| Environmental Sciences |
| Nuclear Science & Technology |
| Scopus |
|---|
| Public Health, Environmental And Occupational Health |
| Radiology, Nuclear Medicine And Imaging |
| Radiological And Ultrasound Technology |
| Radiation |
| SciELO |
|---|
| Sin Disciplinas |
| Ord. | Autor | Género | Institución - País |
|---|---|---|---|
| 1 | GARCIA-LOMA, OMAR FRANCISCO | Hombre |
Ctr Protecc & Higiene Radiaciones CPHR - Cuba
Centro de Protección e Higiene de las Radiaciones (CPHR) - Cuba |
| 2 | Di Giorgio, M. | Mujer |
Autoridad Regulatoria Nucl ARN - Argentina
Inst Invest Biol Clemente Estable - Uruguay Autoridad Regulatoria Nuclear - Argentina Instituto de Investigaciones Bioló gicas Clemente Estable - Uruguay Instituto de Investigaciones Biológicas Clemente Estable - Uruguay |
| 3 | Vallerga, M. B. | - |
Autoridad Regulatoria Nucl ARN - Argentina
Autoridad Regulatoria Nuclear - Argentina |
| 4 | Radl, Analia | - |
Autoridad Regulatoria Nucl ARN - Argentina
Autoridad Regulatoria Nuclear - Argentina |
| 5 | Taja, M. R. | - |
Autoridad Regulatoria Nucl ARN - Argentina
Autoridad Regulatoria Nuclear - Argentina |
| 6 | Seoane, A. | - |
Univ Nacl La Plata CONICET - Argentina
Instituto de GenÉtica Veterinaria Ingeniero Fernando Noel Dulout (CONICET- Universidad Nacional de La Plata) - Argentina |
| 7 | De Luca, J. | - |
Univ Nacl La Plata CONICET - Argentina
Instituto de GenÉtica Veterinaria Ingeniero Fernando Noel Dulout (CONICET- Universidad Nacional de La Plata) - Argentina |
| 8 | Stuck-Oliveira, M. | - |
Inst Radioprotecc & Dosimetria IRD - Brasil
Instituto de Radioprotección y Dosimetría (IRD) - Brasil |
| 9 | Valdivia, P. | Mujer |
Comision Chilena de Energia Nuclear - Chile
Santiago Centro - Chile |
| 10 | Lamadrid, A. I. | - |
Ctr Protecc & Higiene Radiaciones CPHR - Cuba
Centro de Protección e Higiene de las Radiaciones (CPHR) - Cuba |
| 11 | Gonzalez, J. E. | Hombre |
Ctr Protecc & Higiene Radiaciones CPHR - Cuba
Centro de Protección e Higiene de las Radiaciones (CPHR) - Cuba |
| 12 | Romero, I. | - |
Ctr Protecc & Higiene Radiaciones CPHR - Cuba
Centro de Protección e Higiene de las Radiaciones (CPHR) - Cuba |
| 13 | Mandina, T. | - |
Ctr Protecc & Higiene Radiaciones CPHR - Cuba
Centro de Protección e Higiene de las Radiaciones (CPHR) - Cuba |
| 14 | Pantelias, G. | - |
Natl Ctr Sci Res Demokritos - Grecia
Demokritos National Centre for Scientific Research - Grecia National Centre for Scientific Research "DEMOKRITOS" - Grecia |
| 15 | Terzoudi, G. | - |
Natl Ctr Sci Res Demokritos - Grecia
Demokritos National Centre for Scientific Research - Grecia National Centre for Scientific Research "DEMOKRITOS" - Grecia |
| 16 | Guerrero-Carbajal, C. | - |
Inst Nacl Invest Nucl ININ - México
Instituto Nacional de Investigaciones Nucleares - México |
| 17 | Arceo Maldonado, C. | Mujer |
Inst Nacl Invest Nucl ININ - México
Instituto Nacional de Investigaciones Nucleares - México |
| 18 | ESPINOZA-BARRIOS, MONICA CECILIA | Mujer |
Inst Peruano Energia Nucl IPEN - Perú
Instituto Peruano de Energia Nuclear - Perú |
| 19 | Oliveros, N. | - |
Universidad Nacional Mayor de San Marcos - Perú
|
| 20 | Martinez-Lopez, W. | - |
Inst Invest Biol Clemente Estable - Uruguay
Instituto de Investigaciones Bioló gicas Clemente Estable - Uruguay Instituto de Investigaciones Biológicas Clemente Estable - Uruguay |
| 21 | Di Giorgio, M. | Mujer |
Autoridad Regulatoria Nucl ARN - Argentina
Inst Invest Biol Clemente Estable - Uruguay Autoridad Regulatoria Nuclear - Argentina Instituto de Investigaciones Bioló gicas Clemente Estable - Uruguay Instituto de Investigaciones Biológicas Clemente Estable - Uruguay |
| 22 | MENDEZ-ACUNA, LETICIA | Mujer |
Inst Invest Biol Clemente Estable - Uruguay
Instituto de Investigaciones Bioló gicas Clemente Estable - Uruguay Instituto de Investigaciones Biológicas Clemente Estable - Uruguay |
| 23 | Puig, R. | - |
UNIV AUTONOMA BARCELONA - España
Universitat Autònoma de Barcelona - España |
| 24 | Roy, L. | - |
Inst Radioprotect & Surete Nucl IRSN - Francia
IRSN Institut de Radioprotection et de Sureté Nucléaire - Francia |
| 25 | Barquinero, Joan-Francesc | - |
Inst Radioprotect & Surete Nucl IRSN - Francia
IRSN Institut de Radioprotection et de Sureté Nucléaire - Francia |
| Agradecimiento |
|---|
| This work was supported by the International Atomic Energy Agency. Project RLA/9/054-061 Strengthening National Systems for Preparedness and Response to Nuclear and Radiological Emergencies in Latin American Member States (TSA 5). |
| This work was supported by the International Atomic Energy Agency. Project RLA/9/054-061 Strengthening National Systems for Preparedness and Response to Nuclear and Radiological Emergencies in Latin American Member States (TSA 5). |