Muestra métricas de impacto externas asociadas a la publicación. Para mayor detalle:
| Indexado |
|
||||
| DOI | 10.1016/J.ENGSTRUCT.2015.04.037 | ||||
| Año | 2015 | ||||
| Tipo | artículo de investigación |
Citas Totales
Autores Afiliación Chile
Instituciones Chile
% Participación
Internacional
Autores
Afiliación Extranjera
Instituciones
Extranjeras
Seismic protection of wine storage tanks has become a very important issue due to the booming of the wine industry in seismic countries such as the US, Italy, New Zealand, Chile and Argentina. In order to improve the seismic reliabilities of structures, external energy dissipation may be used beneficially. In this study, the reliabilities of two continuously supported cylindrical steel tanks (one slender and one broad), used for fermentation and wine storage, with and without an external energy dissipation system are calculated by using simulation. A group of non-linear time history analyses is established in order to assess the influence of the energy dissipation system. Each non-linear time history is obtained by means of a mathematical model that considers the fluid-structure-soil interaction. A set of different seismic ground motions is used for the purpose of obtaining robust results in the reliability analysis. Finally, the seismic reliability analysis shows that, for steel wine storage tanks, an external energy dissipation system would reduce the limit state probability in the order of 80%. (C) 2015 Elsevier Ltd. All rights reserved.
| Ord. | Autor | Género | Institución - País |
|---|---|---|---|
| 1 | COLOMBO, JOSE IGNACIO | Hombre |
Pontificia Universidad Católica de Chile - Chile
|
| 2 | ALMAZAN-CAMPILLAY, JOSE LUIS | Hombre |
Pontificia Universidad Católica de Chile - Chile
|
| Fuente |
|---|
| FONDECYT |
| CONICYT-PCHA/Doctorado Nacional |
| CONICYT-PCHA |
| Fondo Nacional de Desarrollo Científico y Tecnológico |
| Fondo Nacional de Desarrollo CientÃfico y Tecnológico |
| CONICYT-PCHA/Doctorado |
| DOCTORADO |
| Agradecimiento |
|---|
| The authors wish to acknowledge the financial support provided by CONICYT-PCHA/Doctorado Nacional/2013-63130131 and the FONDECYT project number 1120937. In addition, a particular thank-you is extended to Dr. Praveen Malhotra for his valuable comments on the non-linear dynamic analysis of liquid storage tanks. |
| The authors wish to acknowledge the financial support provided by CONICYT-PCHA/Doctorado Nacional/2013-63130131 and the FONDECYT project number 1120937. In addition, a particular thank-you is extended to Dr. Praveen Malhotra for his valuable comments on the non-linear dynamic analysis of liquid storage tanks. |