Colección SciELO Chile

Departamento Gestión de Conocimiento, Monitoreo y Prospección
Consultas o comentarios: productividad@anid.cl
Búsqueda Publicación
Búsqueda por Tema Título, Abstract y Keywords



A micro-CT evaluation of bone density around two different types of surfaces on one-piece fixo implants with early loading-an experimental study in dogs at 3 months
Indexado
WoS WOS:000910894700001
DOI 10.3934/BIOENG.2022028
Año 2022
Tipo artículo de investigación

Citas Totales

Autores Afiliación Chile

Instituciones Chile

% Participación
Internacional

Autores
Afiliación Extranjera

Instituciones
Extranjeras


Abstract



The study's main objective was to evaluate the bone density and osseointegration around dental implants with two different implant surfaces with early loading, using a micro-CT device. Twenty-four Fixo (R) implants (Oxyimplant, Biomec Italy) 3.5 x 8.5 mm with Laser (test group) and acid-etched surface (control group) were placed in six young beagle dog's mandibles. MicroCT (Albira, Germay) evaluation with seven regions of interest was defined in each implant on two different surfaces. A total of 168 sites were studied, and four isocountours were also done in each implant at coronal, transversal, and sagittal scanned areas to evaluate bone density location. The effect on the bone evaluation of two different surfaces variables was evaluated at the mesial and distal positions, showing crestal, medial, and apical types of bone density. Implant positions (P2, P3, P4, and M1) were also analyzed to determine bone density areas. The results of hard tissue density indicated a statistical significance for laser surface at crestal ROIs level (p < 0.001) and position of implants (p = 0.032)related to P3 areas compared to the acid-etched surface in Fixo (R) implants. Density D4 was the most common type of bone surrounding Fixo (R) standard implants at three different positions and density D3 was the most found on Fixo (R) laser surfaces. Micro-CT evaluation was a powerful tool for measuring the type of bone quality and location surrounding dental implants. Micro-CT study revealed that the most common density type found around Fixo (R) laser surface (test) implants was density D3 at the mesial and distal coronal part and density D4 at the middle and apical part. Fixo (R) implant with acid -etched surface showed the type of density D4 bone in hole implant at 3 months follow-up. It is a complementary histologic and histomorphometric analysis method for implant surrounding bone density.

Revista



Revista ISSN
2375-1495

Métricas Externas



PlumX Altmetric Dimensions

Muestra métricas de impacto externas asociadas a la publicación. Para mayor detalle:

Disciplinas de Investigación



WOS
Engineering, Biomedical
Scopus
Sin Disciplinas
SciELO
Sin Disciplinas

Muestra la distribución de disciplinas para esta publicación.

Publicaciones WoS (Ediciones: ISSHP, ISTP, AHCI, SSCI, SCI), Scopus, SciELO Chile.

Colaboración Institucional



Muestra la distribución de colaboración, tanto nacional como extranjera, generada en esta publicación.


Autores - Afiliación



Ord. Autor Género Institución - País
1 Calvo-Guirado, Jose Luis Hombre Univ Autonomade Chile - Chile
2 Carrillo, Nuria Garcia Mujer UNIV MURCIA - España
3 de Carlos-Villafranca, Felix Hombre Univ Oviedo - España
4 Garces-Villala, Miguel Angel Hombre Fdn Corazon Jesus - Argentina
5 Mahesh, Lanka -
6 Ibanez, Juan Carlos Hombre Catholic Univ Cordoba - Argentina
7 Martinez-Martinez, Francisco Hombre Hosp Clin Univ Virgen Arrixaca - España

Muestra la afiliación y género (detectado) para los co-autores de la publicación.

Financiamiento



Fuente
Sin Información

Muestra la fuente de financiamiento declarada en la publicación.

Agradecimientos



Agradecimiento
Sin Información

Muestra la fuente de financiamiento declarada en la publicación.