Colección SciELO Chile

Departamento Gestión de Conocimiento, Monitoreo y Prospección
Consultas o comentarios: productividad@anid.cl
Búsqueda Publicación
Búsqueda por Tema Título, Abstract y Keywords



The ADR Encoder is a reliable and valid device to measure barbell mean velocity during the Smith machine bench press exercise
Indexado
WoS WOS:000727850200001
Scopus SCOPUS_ID:85121341359
DOI 10.1177/17543371211062811
Año 2021
Tipo artículo de investigación

Citas Totales

Autores Afiliación Chile

Instituciones Chile

% Participación
Internacional

Autores
Afiliación Extranjera

Instituciones
Extranjeras


Abstract



Velocity-based training is a contemporary resistance training method, which uses lifting velocity to prescribe and assess the effects of training. However, the high cost of velocity monitoring devices can limit their use among strength and conditioning professionals. Therefore, this study aimed to examine the reliability and concurrent validity of an affordable linear position transducer (ADR Encoder) for measuring barbell velocity during the Smith machine bench press exercise. Twenty-eight resistance-trained males performed two blocks of six repetitions in a single session. Each block consisted of two repetitions at 40%, 60%, and 80% of their estimated one-repetition maximum. The mean velocity of the lifting phase was simultaneously recorded with the ADR Encoder and a gold-standard linear velocity transducer (T-Force(R) System). Both devices demonstrated high reliability for measuring mean velocity (ADR Encoder: CVrange = 2.80%-6.40% and ICCrange = 0.78-0.82; T-Force(R) System: CVrange = 3.27%-6.62% and ICCrange = 0.77-0.81). The ADR Encoder provided mean velocity at 40%1RM with a higher reliability than the T-Force(R) System (CVratio = 1.17), but the reliability did not differ between devices at higher loads (60%1RM-80%1RM) (CVratio <= 1.08). No fixed or proportional bias was observed for the different loads using least-products regression analysis, while the Bland-Altman plots revealed low systematic bias (0.01 m center dot s(-1)) and random errors (0.03 m center dot s(-1)). However, heteroscedasticity of the errors was observed between both devices (R-2 = 0.103). The high reliability and validity place the ADR Encoder as a low-cost device for accurately measuring mean velocity during the Smith machine bench press exercise.

Métricas Externas



PlumX Altmetric Dimensions

Muestra métricas de impacto externas asociadas a la publicación. Para mayor detalle:

Disciplinas de Investigación



WOS
Engineering, Mechanical
Sport Sciences
Scopus
Engineering (All)
SciELO
Sin Disciplinas

Muestra la distribución de disciplinas para esta publicación.

Publicaciones WoS (Ediciones: ISSHP, ISTP, AHCI, SSCI, SCI), Scopus, SciELO Chile.

Colaboración Institucional



Muestra la distribución de colaboración, tanto nacional como extranjera, generada en esta publicación.


Autores - Afiliación



Ord. Autor Género Institución - País
1 Castilla, Alejandro Perez Hombre UNIV GRANADA - España
Universidad de Granada - España
2 Miras-Moreno, Sergio Hombre UNIV GRANADA - España
Universidad de Granada - España
3 Jose Garcia-Vega, Agustin Hombre UNIV GRANADA - España
Universidad de Granada - España
4 Garcia-Ramos, Amador Hombre UNIV GRANADA - España
Universidad Católica de la Santísima Concepción - Chile
Universidad de Granada - España

Muestra la afiliación y género (detectado) para los co-autores de la publicación.

Financiamiento



Fuente
Sin Información

Muestra la fuente de financiamiento declarada en la publicación.

Agradecimientos



Agradecimiento
Sin Información

Muestra la fuente de financiamiento declarada en la publicación.