Abstract



IntroductionSurgical instrument contamination during total joint replacement is a matter of major concern. Available recommendations suggest changing suction tips, gloves and avoiding light handle manipulation during the procedure. There is a paucity of data regarding surgical gown contamination. The aim of the present study was to evaluate the contamination rate of surgical gowns (SGs) during total hip arthroplasty (THA) and secondarily compare it with other orthopedic procedures.Materials and methodsOne hundred and forty surgical gowns (from 70 surgeries) were screened for bacterial contamination using thioglycolate (a high-sensitivity culture broth). The THA contamination rate was compared with those of knee and spine procedures. Controls were obtained at the beginning of every surgery and from the culture broth. The procedure's duration and the level of training of the surgeon were evaluated as potential risk factors for contamination.ResultsBacterial contamination was identified on 12% of surgical gowns (22% of surgical procedures). The contamination rate during THA was 4.1% (2% in primary THA and 8.3% in revisions) vs 21.67% during other surgeries (spine and knee) (OR 6.15, p=0.012). There were no contaminated SGs during THAs performed in 2h (0/33 SGs) vs 7.5% (3/40) for THAs that took 2h (p=0.25).ConclusionThere was a high rate of SG contamination during orthopedic procedures that was higher during non-arthroplasty procedures and prolonged THAs. There were no contaminated surgical gowns in THAs under 120min, efforts should point keeping primary THAs under this cutoff time. As a general recommendation, SGs should be changed every time there is concern about potential contamination.

Métricas Externas



PlumX Altmetric Dimensions

Muestra métricas de impacto externas asociadas a la publicación. Para mayor detalle:

Disciplinas de Investigación



WOS
Surgery
Orthopedics
Scopus
Sin Disciplinas
SciELO
Sin Disciplinas

Muestra la distribución de disciplinas para esta publicación.

Publicaciones WoS (Ediciones: ISSHP, ISTP, AHCI, SSCI, SCI), Scopus, SciELO Chile.

Colaboración Institucional



Muestra la distribución de colaboración, tanto nacional como extranjera, generada en esta publicación.


Autores - Afiliación



Ord. Autor Género Institución - País
1 Klaber, Ianiv - Pontificia Universidad Católica de Chile - Chile
2 Ruiz, Pablo Hombre Pontificia Universidad Católica de Chile - Chile
3 Schweitzer, Daniel Hombre Pontificia Universidad Católica de Chile - Chile
4 Lira, María Jesús Mujer Pontificia Universidad Católica de Chile - Chile
5 BOTELLO-CORREA, EDUARDO ANDRES Hombre Pontificia Universidad Católica de Chile - Chile
6 Wozniak, Aniela Mujer Pontificia Universidad Católica de Chile - Chile

Muestra la afiliación y género (detectado) para los co-autores de la publicación.

Financiamiento



Fuente
Sin Información

Muestra la fuente de financiamiento declarada en la publicación.

Agradecimientos



Agradecimiento
Sin Información

Muestra la fuente de financiamiento declarada en la publicación.