Radiation dose and image quality for paediatric protocols in a biplane x-ray system used for interventional cardiology have been evaluated. Entrance surface air kerma (ESAK) and image quality using a test object and polymethyl methacrylate (PMMA) phantoms have been measured for the typical paediatric patient thicknesses (4-20 cm of PMMA). Images from fluoroscopy (low, medium and high) and cine modes have been archived in digital imaging and communications in medicine (DICOM) format. Signal-to-noise ratio (SNR), figure of merit (FOM), contrast (CO), contrast-to-noise ratio (CNR) and high contrast spatial resolution (HCSR) have been computed from the images. Data on dose transferred to the DICOM header have been used to test the values of the dosimetric display at the interventional reference point. ESAK for fluoroscopy modes ranges from 0.15 to 36.60 mu Gy/frame when moving from 4 to 20 cm PMMA. For cine, these values range from 2.80 to 161.10 mu Gy/frame. SNR, FOM, CO, CNR and HCSR are improved for high fluoroscopy and cine modes and maintained roughly constant for the different thicknesses. Cumulative dose at the interventional reference point resulted 25-45% higher than the skin dose for the vertical C-arm (depending of the phantom thickness). ESAK and numerical image quality parameters allow the verification of the proper setting of the x-ray system. Knowing the increases in dose per frame when increasing phantom thicknesses together with the image quality parameters will help cardiologists in the good management of patient dose and allow them to select the best imaging acquisition mode during clinical procedures.
| Ord. | Autor | Género | Institución - País |
|---|---|---|---|
| 1 | Vano, E. | Hombre |
UNIV COMPLUTENSE - España
San Carlos Univ Hosp - España Universidad Complutense de Madrid - España |
| 2 | UBEDA-DE LA CERDA, CARLOS ARTURO | Hombre |
Universidad de Tarapacá - Chile
|
| 3 | LEYTON-LEGUES, FERNANDO ALBERTO | Hombre |
Inst Publ Hlth Chile - Chile
Institute of Public Health of Chile - Chile Inst Publ Hlth - Chile |
| 4 | MIRANDA-GONZALEZ, PATRICIA | Mujer |
Hospital Luis Calvo Mackenna - Chile
Hospital Dr. Luis Calvo Mackenna Hospital - Chile Hosp Ninos Luis Calvo Mackenna - Chile |