Design and construction of an anchored soldier pile wall for a large underground car park Diseño y construcción de muro Berlinés para estacionamiento subterráneo de grandes dimensiones
Indexado
WoS WOS:000287119200001
Scopus SCOPUS_ID:78951470620
SciELO S0718-915X2010000200002
DOI 10.4067/S0718-915X2010000200002
Año 2010
Tipo artículo de investigación

Citas Totales

Autores Afiliación Chile

Instituciones Chile

% Participación
Internacional

Autores
Afiliación Extranjera

Instituciones
Extranjeras


Abstract



The geotechnical conditions of the soil and the construction conditions of a retaining wall for an underground two-level car park project are described. The project is located in Concepcion's downtown, south of Chile. The excavation support had to prevent any damage for the Courts of Justice historic building and surrounding buildings. These are buildings between four and nine floors and the Hites building is also classified as a historical building. Also, any cutoff of water, sewage, gas and electricity had to be avoided. The solution adopted was an anchored soldier pile wall of 8 m depth around the excavation, where the soldier piles (H section steel piles) were driven into semi dense silty sand. Two lines of anchors were designed vertically and horizontally separated by 3 m and 3.2 m respectively. The design loads for the anchors ranged between 300 and 560 kN respectively. The installation and placement of anchors was studied in order not to disturb the different stages of construction. The project included 3596 m(2) of anchored soldier pile wall with 314 post-stressed anchors and 300 soldier piles totalling 3200 m. It is concluded that the temporary excavation support solution adopted performed properly to the high demands set, since no important deformations were noted in the building of Courts of Justice, in the surrounding buildings or in the services of drinking water, power, gas or electricity. The city of Concepcion was severely struck by an 8.8 moment magnitude earthquake on the 27(th) February 2010. The construction of the underground car park was just ready when the earthquake occurred. No damage was observed in the car park due to the seismic event. It is believed that the buried soldier pile wall reduced the seismic loads acting on the underground car park structure since no evidence of damage exists after the very big earthquake.

Revista



Revista ISSN
Revista De La Construccion 0717-7925

Métricas Externas



PlumX Altmetric Dimensions

Muestra métricas de impacto externas asociadas a la publicación. Para mayor detalle:

Disciplinas de Investigación



WOS
Sin Disciplinas
Scopus
Civil And Structural Engineering
Building And Construction
SciELO
Sin Disciplinas

Muestra la distribución de disciplinas para esta publicación.

Publicaciones WoS (Ediciones: ISSHP, ISTP, AHCI, SSCI, SCI), Scopus, SciELO Chile.

Colaboración Institucional



Muestra la distribución de colaboración, tanto nacional como extranjera, generada en esta publicación.


Autores - Afiliación



Ord. Autor Género Institución - País
1 VILLALOBOS-JARA, FELIPE ALBERTO Hombre Universidad Católica de la Santísima Concepción - Chile
Universidad de Concepción - Chile
2 Orostegui, Paulo L. Hombre Constructora Lancuyen Ltda - Chile
Constructora Lancuyen Ltda. - Chile

Muestra la afiliación y género (detectado) para los co-autores de la publicación.

Financiamiento



Fuente
Sin Información

Muestra la fuente de financiamiento declarada en la publicación.

Agradecimientos



Agradecimiento
Sin Información

Muestra la fuente de financiamiento declarada en la publicación.